Testo 315-1, CO leakage alarm device testo 315-1
Teste 315-1, CO Leakage AlarmCO leakage may cause a risk of poisoning. Teste 315-1 detects the CO content in indoor air and simultaneously measures pressure, wind speed, ionization current, and temperature It is an ideal instrument for safe maintenance of gas heating systems. The testo printer prints data, address, date, time, and alarm limits on-site.
- Testo 315-1, CO leakage alarm device
- ZHUOXIN
- 24-380v
- IP65
- TT, Paypal, Credit card, Western union
- +86-15163766288
- Teste 315-1, CO Leakage AlarmCO leakage may cause a risk of poisoning. Teste 315-1 detects the CO content in indoor air and simultaneously measures pressure, wind speed, ionization current, and temperature It is an ideal instrument for safe maintenance of gas heating systems. The testo printer prints data, address, date, time, and alarm limits on-site.
Description
Testo 315-1, CO leakage alarm device, including battery and factory report& nbsp; Product introduction: CO leakage may lead to poisoning hazards. Teste 315-1 detects the CO content in indoor air and simultaneously measures pressure, wind speed, ionization current, and temperature< Br/>It is an ideal instrument for safe maintenance of gas heating systems. The testo printer prints data, address, date, time, and alarm limits on-site& nbsp; Advantages: 3 CO alarm limits, optional sound and light alarm when exceeded. DVGW certification on-site for quick data archiving, printing data, time, date, and recommended values (alarm limits). Temperature compensation does not need to be zeroed in fresh air
Technical parameters Storage temperature -20~+50; C Operating temperature+5~+45; C Battery type 9V block battery, battery life 16 hours, weight 400 g, size 215 x 68 x 47 mm, shell material ABS Temperature measurement (K-type thermocouple); Range -40~+600; C Precision± 0.5% measurement value (+100~+600° C)
± 0.5° C (0~+99° C); C) Resolution 0.1; C (-40 ~ +600 ° C) Current probe; Range -100~+100µ A Precision± 3 µ A (-100 ~ +100 µ A) Resolution 1µ A (-100 ~ +100 µ A) Differential pressure measurement 1 (piezoresistive pressure sensor); Range -200~+200 hPa Accuracy± 0.5 hPa (-49.9 ~ +49.9 hPa)
± 1.5 hPa (-200 ~ -50 hPa)
± 1.5 hPa (+50~+200 hPa) resolution 0.1 hPa (-200~+200 hPa) differential pressure measurement 2 (piezoresistive pressure sensor); Range -40~+40 hPa Accuracy± 1.5% measured value (-40~-3 hPa)
± 1.5% measured value (+3~+40 hPa)
± 0.03 hPa (-2.99~+2.99 hPa) resolution 0.01 hPa (-40~+40 hPa) electrochemical CO sensor; Range 0~+2000 ppm CO Resolution 1 ppm CO (0~+2000 ppm CO) LFX80A3-40-Z/P LFX80A3-40-Z/N LFX80A3-40-Z/PU LFX80A3-40-Z/NU LFX118A3-20-Z/P LFX118A3-20-Z/N LFX118A3-20-Z/PU LFX118A3-20-Z/NU LFX48A3-20-Z/P LFX48A3-20-Z/N LFX48A3-20-Z/PU LFX48A3-20-Z/NU LFX30A3-10-Z/P LFX30A3-10-Z/N LFX30A3-10-Z/PU
Technical parameters Storage temperature -20~+50; C Operating temperature+5~+45; C Battery type 9V block battery, battery life 16 hours, weight 400 g, size 215 x 68 x 47 mm, shell material ABS Temperature measurement (K-type thermocouple); Range -40~+600; C Precision± 0.5% measurement value (+100~+600° C)
± 0.5° C (0~+99° C); C) Resolution 0.1; C (-40 ~ +600 ° C) Current probe; Range -100~+100µ A Precision± 3 µ A (-100 ~ +100 µ A) Resolution 1µ A (-100 ~ +100 µ A) Differential pressure measurement 1 (piezoresistive pressure sensor); Range -200~+200 hPa Accuracy± 0.5 hPa (-49.9 ~ +49.9 hPa)
± 1.5 hPa (-200 ~ -50 hPa)
± 1.5 hPa (+50~+200 hPa) resolution 0.1 hPa (-200~+200 hPa) differential pressure measurement 2 (piezoresistive pressure sensor); Range -40~+40 hPa Accuracy± 1.5% measured value (-40~-3 hPa)
± 1.5% measured value (+3~+40 hPa)
± 0.03 hPa (-2.99~+2.99 hPa) resolution 0.01 hPa (-40~+40 hPa) electrochemical CO sensor; Range 0~+2000 ppm CO Resolution 1 ppm CO (0~+2000 ppm CO) LFX80A3-40-Z/P LFX80A3-40-Z/N LFX80A3-40-Z/PU LFX80A3-40-Z/NU LFX118A3-20-Z/P LFX118A3-20-Z/N LFX118A3-20-Z/PU LFX118A3-20-Z/NU LFX48A3-20-Z/P LFX48A3-20-Z/N LFX48A3-20-Z/PU LFX48A3-20-Z/NU LFX30A3-10-Z/P LFX30A3-10-Z/N LFX30A3-10-Z/PU
Tags
Get the latest price? We'll respond as soon as possible(within 12 hours)