夜色88v精品国产亚洲av,亚洲性视频,吃奶揉捏奶头高潮视频在线观看 ,av在线观看网址

Conveyor switch

Fully sealed waterproof FSSL-III bidirectional pull rope switch FSSL-III

The fully sealed waterproof FSSL-III bidirectional rope switch is installed on the frames on both sides of the belt conveyor, and the switch is connected along both sides of the conveyor with a steel wire rope. When an emergency occurs in the conveyor belt equipment, the steel wire rope is pulled at any location along the site, and the steel wire rope drives the drive arm to rotate. The precision cam is displaced by the torque spring driven by the transmission shaft, and the micro switch is driven to cut off the control line, causing the conveyor to stop running.

  • Fully sealed waterproof FSSL-III bidirectional pull rope switch
  • ZHUOXIN
  • 24-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • The fully sealed waterproof FSSL-III bidirectional rope switch is installed on the frames on both sides of the belt conveyor, and the switch is connected along both sides of the conveyor with a steel wire rope. When an emergency occurs in the conveyor belt equipment, the steel wire rope is pulled at any location along the site, and the steel wire rope drives the drive arm to rotate. The precision cam is displaced by the torque spring driven by the transmission shaft, and the micro switch is driven to cut off the control line, causing the conveyor to stop running.

Description

Conveyor switch

The fully sealed waterproof FSSL-III bidirectional rope switch is composed of a pull rod, a reset handle, a cam, a locking groove, and a micro switch. The pull rope switch is installed on the frames on both sides of the belt conveyor, and is connected along both sides of the conveyor with a steel wire rope. When an emergency occurs in the conveyor belt equipment, the steel wire rope is pulled at any location along the site, and the steel wire rope drives the drive arm to rotate. The precision cam is displaced by the torque spring driven by the transmission shaft, and the micro switch is driven to cut off the control line, causing the conveyor to stop running. The installation and adjustment rope switch should be installed in a location with maintenance channels on both sides of the conveyor, and the installation position should ensure that maintenance personnel can operate conveniently in emergency situations. 1. Fix the rope switch on the rack. 2. The distance between the two switches on one side is about 50m, using a diameter ofΦ The steel wire rope connection of 4 should have moderate elasticity. 3. To reduce the impact of the weight of the steel wire rope on the start of the switch, a support ring is installed on the frame every 3 meters to support the steel wire rope. 4. The other end of the steel wire rope is tied to the tension spring (fixed with a rope buckle), and the tension on both sides of the rope is tightened using a tightener without affecting normal use, ensuring that the tension on both sides is balanced. (Note: For the climbing section conveyor, the switch spacing and rope length should be minimized as much as possible.) Precautions: 1. Cut off the main power supply first, and then use a multimeter to measure the live wire. The switch must be installed at one end of the live wire. 2. Cut the live wire in a suitable place, and there are two joints, and the pull switch also has two joints. 3. Peel off the two joints of the live wire and expose the metal wire, and connect them to either of the two joints of the switch. 4. Cut off the excessively long metal wire at the connected joint to prevent two metal wires from colliding and short circuiting. 5. Loosen the cover of the pull switch and you can see a metal shaft with a hole at one end. 6. There is also a hole on the side of the plastic casing of the pull switch. First, pass the pull wire through the opening of the plastic casing to introduce the pull wire into the pull switch. Then, insert one end of the introduced pull wire into the shaft and tie a knot. Shorten the excessively long pull wire after tying. 7. Rotate the cover of the cable switch to prevent electric shock. The steel wire rope of FSSL-III and FSSL-111 bidirectional pull rope switches is fixed on one end of a fixed pull bolt, and the other end is fixed on the other end; On the switch arm, the steel wire rope should be supported by a perforated bolt every 3 meters, and the distance from the switch to the fixing point should be; Not exceeding 30 meters, and the distance between the two switches not exceeding 60 meters. When external force drives the switch arm to rotate to the alarm position; When in the alarm position, touch the microswitch and lock it until it is manually reset. Suitable for indoor and outdoor installation. Special surface treatment can be used for acidic, alkaline, and saline areas. Nickel plated surfaces are used in highly corrosive areas. YB3205 AC power supply/YB-3205; D5 handheld laser rangefinder/D-5; YB1731A2A DC stabilized power supply/YB-1731A; LinoL2 marking instrument/Lino-L2; YB1731A DC stabilized power supply/YB-1731A; YB1731A DC stabilized power supply/YB-1731A; YB1731B DC stabilized power supply/YB-1731B; CY2663A Voltage and Insulation Tester; CY2666 withstand voltage tester; NAK2 level/NAK-2; CY2671 Universal breakdown voltage tester/CY2671; JOGGER20 level/JOGGER-20; JOGGER24 level/JOGGER-24; DSZ2 level/DSZ-2; DSZ2+FS1 level/DSZ-2+FS-1; J2-2 Theodolite/J22; CY2121 Electrical Parameter Comprehensive Tester/CY2121; DT202C Theodolite/DT-202C; CY2141 Electrical Parameter Comprehensive Tester/CY2141; DT205D Theodolite/DT-205D; CY2142 Electrical Parameter Comprehensive Tester/CY2142; CY2142A Electrical Parameter Comprehensive Tester/CY2142AQSL-8, QSL-10, QSL-15, QSL-20, QSL-25, QSL-32, QSL-40, QSL-50, QTY-8, QTY-10, QTY-15, QTY-20, QTY-25, QTY-40, QTY-50, QIU-8, QIU-10, QIU-15, QIU-20, QIU-25, QIU-40, QIU-50394-G1/8394-G1/2394-G3/4394-G3/4394-G1494.21 (G1/8″), 494.22 (G1/4″), 494.35 (G3/8″), 494.36 (G1/2″), 494.48 (G3/4″), 494.49 (G1″), AF2000-01 G1/8, AF2000-02 G1/4, AF3000-03 G3/8, AF4000-03 G3/8, AF4000-04 G1/2, AF4000-06 G3/4, AF5000-06 G3/4, AF5000-10 G1, AF2000, BF2000, BF3000, BF4000, UF-02, UF-03 UF-04, UF-06, UF-08, F-200A, QSLH-15394-8394-15394-25, AF-150, AF-200, F-10, F-20, F-30, F-200, F-300, F-400, F-600, F-4000, F-6000, F-8000 pressure reducing/regulating valves 495.212 (G1/8″), 495.222 (G1/4″), 495.252 (G3/8″), 495.262 (G1/2″), 495.282 (G3/4″), 495.292 (G1″), AR2000-01 G1/8,AR2000-02 G1/4,AR3000-02 G1/4,AR3000-03 G3/8,AR4000-03 G3/8,AR4000-04 G1/2,AR4000-06 G3/4,AR5000-06 G3/4,AR5000-10 G1,AR2000,BR2000,BR3000,BR4000,UR-02,UR-03,UR-04,UR-06,UR-08,R-200A,NR200,R200,QTYH-15,395-G1/8,395-G1/4,395-G3/8,395-G1/2,395-G3/4,395-G1,395-8,395-15,395-25,AR-150,AR-200R-10, R-20, R-30, R-200, R-300, R-400, R-600, R-4000, R-6000, R-8000 oil mist eliminators 496.21 (G1/8″), 496.22 (G1/4″), 496.35 (G3/8″), 496.36 (G1/2″), 496.48 (G3/4″), 496.49 (G1″), AL2000-01 G1/8, AL2000-02 G1/4, AL3000-02 G1/4, AL3000-03 G3/8, AL4000-03 G3/8, AL4000-04 G1/2, AL4000-06 G3/4, AL5000-06 G3/4, AL5000-10 G1, AL2000, BL2000, BL3000, BL4000, UL-02, UL-03, UL-04, UL-06, UL-08, L-200A, SL2000, SL3000, SL4000396-G1/8396-G1/2396-G3/4396-G3/4396-G396-G1396-8396-153996-25, AL-15 0, AL-200, SL-200, SL-300, SL-400, L-10, L-20, L-30, L-200, L-300, L-400, L-600, L-4000, L-6000, L-8000 filter pressure reducing valve/regulating filter 497.212 (G1/8″), 497.222 (G1/4″), 497.262 (G1/2″), 497.282 (G3/4″), 497.292 (G1″), AW2000-01 G1/8, AW2000-02 G1/4, AW3000-02 G1/4, AW3000-03 G3/8, AW4000-03 G3/8, AW4000-04 G1/2, AW4000-06 G3/4, AW5000-06 G3/4, AW5000-10 G1, AFR2000, BFR2000, BFR3000, BFR4000, UFR-02, UFR-03, UFR-04, UFR-06, UFR-08, FR-500A, SFR2000, SFR3000, SFR4000397-G1/8397-G1/2397-G1/4397-G3/8397-G1/2397-G34397-G3/4397-G7 G1397-8397-15397-25, FR-500A, SFR200, SFR300, SFR400, AFR-150, AFR-200, FR-10, FR-20, FR-30, FR-200, FR-400, FR-600, FR-4000, FR-6000, FR-8000 Triplet 498.212 (G1/8″), 498.222 (G1/4″), 498.252 (G3/8″), 498.262 (G1/2″), 498.282 (G3/4″), 498.292 (G1″), AC2000-01 G1/8, AC2000-02 G1/4, AC3000-02 G1/4, AC3000-03 G3/8, AC4000-03 G3/8, AC4000-04 G1/2, AC4000-06 G3/4, AC5000-06 G3/4, AC5000-10 G1, AC2000, BC2000, BC2000, BC3000, BC4000, UFRL-02, UFRL-03, UFRL-04, UFRL-06, UFRL-08, FRL-700A, 398-G1/8398-G1/4398-G3/8398-G1/2398-G3/4398-G398-G1398-8398-153998-25, AC-150, AC-200, C-10, C-20, C-30, C-200, C-300, C-400, C-600, C-4000, C-6000, C-8000, two-part 499.212 (G1/8″), 499.222 (G1/4″), 499.252 (G3/8″), 499.262 (G1/2″), 499.282 (G3/4″), 499.292 (G1″), AC2010-01 G1/8, AC2010-02 G1/4, AC3010-02 G1/4, AC3010-03 G3/8, AC4010-03 G3/8, AC4010-04 G1/2, AC4010-06 G3/4, AC5010-06 G3/4, AC5010-10 G1, AFC2000, BFC2000, BFC3000, BFC4000, UFR/L-02, UFR/L-03, UFR/L-04, UFR/L-06, UFR/L-08, FRL-600A, SFC2000, SFC3000, SFC4000399-G1/8399-G1/8399-G1/231 99-G3/4399-G1399-8399-15399-205, SFC200, SFC300, SFC400, AFC-150, AFC-200, FC-10, FC-20, FC-30, FC-200, FC-300, FC-400, FC-400, FC-600, FC-4000, FC-6000, FC-8000 precision pressure reducing valves IR1000-01, IR1010-01, IR1020-01, IR2000-02, IR2010-02, IR20220-02, IR3010-02 with automatic drainage AW2000-02D, AW3000-02D, AW3000-03D, AW4000-03D, AW4000-03D, AW4000-04D, AW4000-06D, AW5000-10D Filter with Automatic Drainage AF2000-02D, AF3000-02D, AF3000-03D, AF4000-03D, AF4000-04D, AF4000-06D, AF5000-06D, AF5000-10D Triple piece with Automatic Drainage AC2000-02D, AC3000-02D, AC3000-03D, AC4000-03D, AC4000-04D, AC4000-06D, AC5000-06D, AC5000-10D Dual piece with Automatic Drainage AC2010-02D, AC5000-10D 3010-02D, AC3010-03D, AC4010-03D, AC4010-04D, AC4010-06D, AC5010-06D, AC5010-10D automatic drain SA402, AD402, NP-16B, NP-II, ZDFS, SDV-400-A air source processor new AC20-02, AC20-02D, AC20-02E,AC20-02DE,AC30-02,AC30-02D,AC30-02DE,AC30-03,AC30-03D,AC30-03DE,AC40-04,AC40-04D,AC40-04DE,AC50-06,AC50-06D,AC50-06DE,AC50-10,AC50-10D,AC50-10DE,AC20A-02,AC20A-02D,AC20A-02E, AC20A-02DE,AC30A-02,AC30A-02D,AC30A-02E,AC30A-02DE,AC30A-03,AC30A-03D,AC30A-03E,AC30A-03DE,AC40A-04,AC40A-04D,AC40A-04E,AC40A-04DE,AF20-02,AF20-02D,AF30-02,AF30-03D,AF40-04,AF40-04D,AF50-06,AF50-06D,AF50-10,AF50-10D,AR20-02,AR20-02E,AR30-02,AR30-02E,AR30-03,AR30-03E,AR40-04,AR40-04E,AR50-06,AR50-06E,AR50-10,AR50-10E,AL20-02,AL30-02,AL30-03,AL40-04,AL-50-06,AL50-10,AW20-02,AW20-02D,AW20-02E,AW20-02DE,AW30-02,AW30-02D,AW30-02E, AW30-02DE,AW30-03,AW30-03D,AW30-03DE,AW40-04,AW40-04D,AW40-04E,AW40-04DE 

Tags

Get the latest price? We'll respond as soon as possible(within 12 hours)
japanese酒醉侵犯| 娇妻被交换粗又大又硬无| 东北女人毛多又黑a片| 秋霞成人午夜鲁丝一区二区三区| 久久无码人妻丰满熟妇区毛片| 国产a片| 精品少妇无码av无码专区| 欧美在线精品一区二区三区不卡| 1313久久国产午夜精品理论片| 伸进内衣揉捏她的乳尖| 猛烈的打扑克的视频| 成人试看120秒体验区| 学长别揉了我快尿了男男| 最新精品国偷自产在线69| 浪荡受np双性合集| 日韩人妻精品一区二区三区视频| 亚洲色在线| 边啃奶头边躁狠狠躁av| 人妻少妇久久中文字幕| 精品无人妻一区二区三区| 99久久精品费精品蜜臀av| 337p粉嫩日本亚洲大胆艺术| 欧洲美熟女乱又伦| 娇妻被朋友日出白浆抖内| 精品丝袜av在线观看视频| 免费看片a级毛片免费看| 啊灬啊灬啊灬快灬高潮了| 精品国产乱码久久久久久1区2区| 久久久久亚洲av成人片 | 国产精品女a片爽视频爽| 高h猛烈失禁潮喷a片在线观看| 将军与娇妻各种做高h| 小雪被老外黑人撑破了视频| 成人性爱视频在线观看| 樱桃视频影院在线播放| 国产美女极度色诱视频www| 黄瓜视频在线观看| 欧美另类丰满熟妇乱xxxxx| 公交车强摁做开腿呻吟| 我的兔子好软水好多在线看| 美妇身上销魂冲刺享受|